Color Measurement Analysis Instruments NR110
  • Seller Shenzhen 3NH Technology Co., Ltd.
  • Min. Order 1 Unit/Units
  • FOB Price US $200-1080 /Unit

Item Details

Port: shenzhen
Supply Ability: 10000 Unit/Units per Week
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram

Product Description

Color measurement analysis instruments NR110

NR110 features:

1. Double Locating: Illuminating locating and cross locating

2. Double Measurement End Face: Large area measurement and small area measurement

3. New Integrating Sphere Design: More stable measurement

4. Equipped with Rechargeable High-Capacity Li-ion Battery

NR110 specifications:

Illuminating/Viewing Geometry

8/d

Measuring Aperture

Φ4mm

Detector

Silicon photoelectric diode

Locating

Illuminating Locating/Cross Locating

Measurement End Face

Large stable end-face and small concave-convex end-face

Color Space

CIEL*a*b*C*h* CIEL*a*b*

CIEXYZ

Color Difference Formula

delta E*ab delta L*a*b* E*C*h*

Light Source

D65

Light Source Device

LED blue light excitation

Errors Between Each Equipment

≤0.80 delta E*ab

Storage

100pcs standards 20000pcs samples

Repeatability

Standard deviation within E*ab 0.08

Average of 30 measurements of standard white plate

Language

English/Chinese

Weight

450g

Dimension

205×67×80 mm

Power source

Rechargeable lithium-ion battery [email protected]

Lamp Life

3 years, more than 1.6 million measurements

Charging Time

8 hours--100% electricity

PC Software

CQCS3 Software

Printer (optional)

Miniature thermal printer

NR110 colorimeter

Illuminating Locating, Cross Locating, Large Stable End Face, Small Concave-Convex End Face. (for NR110 Precise Colorimeter )

Company information

Shenzhen 3nh Technology Co., Ltd. is a high-tech enterprise. We research, develop, produce and market photoelectric detection products in photoelectric detection technology field and color management field. After years of intensive research, 3nh launched NH series colorimeter with high precision and high stability, high definition ISO12233 resolution test chart, optical image test solution and specific standard illuminant which are widely used in plastic, electronic, paint, ink, textile, garment, printing and dyeing, food, medical, cosmetic, optical image test industries and the field of scientific research, school and laboratory. Our products are exported around the world. We can provide customization service which has been well received by customers.

Colorimeter products

Company Cerfications

FAQ:

1. When I received NH310/NH300 colorimeter and perform measurement, why the measured data is abnormal?

After receiving NH310/NH300, you have to perform white and black calibration manually when first starting.

2. In which condition, manual white and black calibration and auto calibration are required for NH310?
a. It’s needed to perform manual calibration for NH310 when first starting.
b. In the subsequent starting, NH310 will perform auto calibration at startup. No need to perform manual calibration.
c. Suggestion: it’s best to perform manual calibration once a week or when NH310 measured data is not accurate.

3. In which condition, manual white and black calibration for NH300 is required?
a. It’s needed to perform manual calibration for NH300 when first starting.
b. In the subsequent starting, no need to perform manual calibration.
c. Suggestion: it’s best to perform manual calibration once a week or when NH300 measured data is not accurate.

4. How to replace NH310 measuring aperture?
There are three measuring apertures for NH310: Φ8mm (standard accessory), Φ4mm (standard accessory), extended Φ8mm (optional accessory)
a. Turning on
b. Removing measuring aperture, install the needed measuring aperture.
c. Select “Settings-Aperture Setting” in main menu to select corresponding measuring aperture.
d. After selecting aperture, the instrument will display “White and Black Calibration” interface. White and black calibration must be performed.
e. Replace completed.

5. CQCS3 (Color Quality Control System) Installation

a. Before installation, please Copy CQCS3 folder to your computer and don’t remove any files in CQCS3 folder.
b. Double-click the setup.exe to install CQCS3 software.
c. Then double-click Install.bat under the CQCS3\USB_Driver file to install the driver.
d. Detailed installation information please read the "Installing Software" under CQCS3 User manual.doc.

Company Factory

Warranty:

Color measurement analysis instruments NR110 is under warranty for 12 months from the purchase date. Customers must provide warranty card and valid proof of purchase.